Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 825-830, 2020.
Article in Chinese | WPRIM | ID: wpr-819095

ABSTRACT

OBJECTIVE: To establish the method for simultaneous determination of four known related substances (olmesartan,olmesartan ester dimer ,olmesartan ester alkene ,benzothiadiazine impurity ,called impurity A ,B,C,D for short )in Olmesartan medoxomil hydrochlorothiazide tablets. METHODS :HPLC-principal component self-control with correction factor were adopted. The determination was performed on YMC-Triart C 8 column with mobile phase A consisted of acetonitrile- 0.015 mol/L potassium dihydrogen phosphate solution (pH adjusted to 2.8 with phosphoric acid )(70 ∶ 30,V/V),mobile phase B consisted of acetonitrile-0.015 mol/L potassium dihydrogen phosphate solution (pH adjusted to 2.8 with phosphoric acid )(15 ∶ 85,V/V)at the flow rate of 0.8 mL/min(gradient elution ). The detection wavelength was set at 265 nm,and column temperature was 25 ℃. The temperature of injector was 4 ℃;the injection volume was 10 μL. RESULTS:The correction factors of impurity A ,B,C,D were 1.42,1.17,0.89,0.92,respectively. The linear range of olmesartan medoxomil ,hydrochlorothiazide and impurity A ,B,C,D were 0.252 7-7.580 0,1.152 1-4.562 9,0.244 0-18.299 0,0.244 7-3.670 8,0.265 2-3.978 3 and 0.149 9-4.497 3 μg/mL(r≥ 0.999 7),respectively. The limits of detection were 0.084 2,0.050 7,0.081 3,0.081 6,0.088 4,0.050 0 μg/mL,respectively. The quantitative limits were 0.252 7,0.152 1,0.244 0,0.244 7,0.265 2 and 0.149 9 μg/mL,respectively. The results of intermediate precision ,stability(24 h)and repeatability tests all met the relevant requirements. The average recovery rates were 104.00%-108.04%,102.00%-104.94%,100.99%-106.89%,92.00%-95.18%,102.00%-105.06%,103.90%-107.00%(n=3), respectively. The contents of impurity A ,B and D in 3 batches of Olmesartan medoxomil hydrochlorothiazide tablets were 0.90% -1.00% ,0-0.11% ,0.16% -0.24% ,respectively. The impurity C and other impurities were not detected. There is no significant difference between the results measured by the established method and by the external standard method. CONCLUSIONS:The method has been proved to be highly sensitive and reproducible. It can be used to simultaneously determine four known substances in Olmesartan medoxomil hydrochlorothiazide tablets.

SELECTION OF CITATIONS
SEARCH DETAIL